Request a Quote » Contact Us »
Distributor Login

Welcome to PSL's Download Center

Please Login or Register to Access All Available Downloads

Register

First Time Users Register Here

  • *Required Fields
  • This field is for validation purposes and should be left unchanged.

Enterprise Solution: QubeView

QubeView Whats New Release 1.4.17.707 pdf 364 KB
QubeView Software (90 day trial) zip 32 MB

Firmware and Configurator

Before you update your firmware, please verify that your PQube 3 presently runs with firmware version 3.4.3 or higher.

If it does not have 3.4.3 or higher, you must first update your PQube3 to version 3.4.3 – see instructions below.

If your present firmware version is lower than 3.3.3A, please contact support@powerstandards.com

 

IMPORTANT: This firmware update may take 10 minutes or more to complete.

Do not power off or restart your PQube 3 during the update process.

The firmware update can be done remotely via the Web pages or locally with a USB thumb drive.

When using a USB thumb drive, make sure to first format the thumb drive with Windows.

Make sure that your PQube 3 is up and running before inserting the thumb drive into the USB slot.

Firmware Update Instructions pdf 904 KB
PSL_FIRMWARE_3.7.4.19.06.06 pq3 26 MB
PSL Firmware 3.7.4 Release Notes pdf 954 KB

After upgrading firmware, download and upgrade your Setup.ini using the configurator program.

PQube 3 Configurator 3.7.1.8 zip 2 MB

For Older Firmware : UPDATE to FIRMWARE Version 3.4.3

PSL_FIRMWARE_3.4.3.16.07.22.PQ3 pq3 27 MB

This firmware update is compatible with PQube 3s running firmware 3.3.3A or higher.

If your firmware version is lower than 3.3.3A, please contact support@powerstandards.com

IMPORTANT: This firmware update can take up to 20 minutes to complete.

Do not power off or restart your PQube 3 during the update process.

The firmware upgrade will reset to zero your PQube 3 energy accumulators (kWh,kVAh,kVARh).

The energy accumulator start dates are also set to the date of firmware upgrade

The firmware update can be done remotely via the Web pages or locally with a USB thumb drive.

When using a USB thumb drive, make sure to first format the thumb drive with Windows.

Make sure that your PQube 3 is up and running before inserting the thumb drive into the USB slot.

Instructions

If your PQube 3 has firmware 3.3.3A, 3.3.4, 3.3.5 or 3.3.5F, you must use this file:

3.3.3A, 3.3.4, 3.3.5 or 3.3.5F Firmware Update tar 73 MB

* do not unzip this tar file

If your PQube 3 has firmware 3.4.0, you must use this file:

PSL_FIRMWARE_3.4.3.16.07.22.PQ3 pq3 27 MB

 

Software

PQube 3 Modbus Client

New Modbus Client for PQube 3.
Also supports PQube Classic.

Modbus Client 3.7.0 zip 609 KB
PQube 3 Modbus Reference Manual v1.10 pdf 3 MB

Highlights

  • Remotely verify your connection
  • Real time scope meter with waveforms
  • Real time Voltage and current harmonics
  • Real time 2 kHz – 150 kHz supra harmonics
  • NEW: 4-quadrant energy counters (Wh, Vah, VARh, PF)
  • Easily access over 3000 parameters
  • Recording of live meter values in CSV files

PQube 3 Report Writer

Report Writer is a Window application that compiles and generates Reports for You! It is compatible with both PQube Classic and PQube 3 measurement data, and yes, it is free.

• The output is a fully formatted Microsoft Word document – if necessary, you can than add and edit the contents to your needs (requires Microsoft Word 2007 or later)
• Comes with a series of default report types (EN50160 compliance, Harmonics, Energy consumption…), but can also be customized
• Supports international languages: comes with English, French, Spanish, German, Italian, Dutch, Portuguese, Polish, Slovenian, Croatian. It is easy to add your own language via a dictionary
• Customizable to your business: your logo, your web site displays on the report header
• Customizable to your application: you can create the contents of your report out of dozens of available parameter measurements

Latest features:
• Added reporting of all PQube 3 current channels, analog and digital channels:
neutral and ground current, I6, I7, I8 (and I9 through I14 for PQube 3 e), AN1-A, AN2-E, AN3-E, AN4-E, DIG channels
• Added reporting of environmental parameters (ENV2): ambient temperature, barometric pressure, humidity, acceleration:
• Added reporting of HF impulse events (with a pass/fail based on magnitude threshold)
• Added reporting of RVC (rapid voltage changes) events
• Added reporting of the 2kHz-150kHz conducted emissions
• Added sags/swell/ interruptions charting to an ITIC chart
• Reports specific to harmonics evaluation: select [Harmonics]
> Each voltage and current harmonic ranks are assessed against individual thresholds (default thresholds for voltage refer to EN50160, and they are modifiable individually).
> voltage and current interharmonics are also individually assessed against user definable thresholds
> THD, and TDD or THDi are also assessed against thresholds
• Reports specific to Power consumption evaluation: select [Energy]
> frequency, voltage magnitude/fluctuations are assessed against thresholds
> voltage unbalance, load current profile, active, reactive power, power factor are reported and charted.
> energy daily consumption is charted over the time period of the report
• Added National specific compliance standard for Costa Rica
• Added National specific compliance standard for Sweden (EIFS 2013)
• Additional languages are supported, with the help of our distributors, but you can also add your own language easily (contact support@powerstandards.com , we are happy to help).
• And lots of bug fixes and charting improvements

Download:

Report Writer zip 49 MB

Sample reports from the PQube Report Writer

Sample EN50160 Report-English pdf 541 KB
Exemple de EN50160 Rapport - Français pdf 543 KB
Beispiel EN50160 Report - Deutsch pdf 595 KB
Exemplo EN50160 Relatório - Português pdf 338 KB
Ejemplo EN50160 Reporte - Español pdf 544 KB


GIF Generator

PSL GIF Generator zip 2 MB

Power Standards Lab
980 Atlantic Ave.
Alameda, California 94501

contactus@powerstandards.com
TEL: ++1.510.522.4400
US: 1.888.SEMI.F47 or 1.888.736.4347

Join Our Email List!

Lean on our power quality expertise, so you can focus on what you do best
  • This field is for validation purposes and should be left unchanged.